A NOVEL UPLC METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF ABAMECTIN AND PRAZIQUANTEL IN BULK AND PHARMACEUTICAL DOSAGE FORM
Syeda Sana Saima* and Iffath Rizwana
Abstract
A new simple, accurate, precise, and robust Ultra performance liquid
chromatography (UPLC) was developed and validated for
simultaneous estimation of Abamectin and Praziquantel. The
separation was achieved by using the combination of Acetonitrile:
water: methanol in ratio (40:30:30) in zodiac C18 columnC18
(250×4.6 ID× 5μm) with a Flow rate of 1.0 ml/min at a wavelength of
244nm. Abamectin and Praziquantel were eluted at the retention time
of 2.3 and 4 mins respectively. System suitability parameters are found
to be within limits. Method produces linear responses within the
concentration range 1535μg/ml for Abamectin and 40-120μg/ml for
Praziquantel. The method was found to be accurate as the percentage recovery was 99.6 %
and 98 % for ABM and PRQ and was within the limits. LOD was found to be 0.21μg/ml for
abamectin and 2.09μg/ml for praziquantel LOQ was found to be 0.65μg/ml for abamectin
and 6.35μg/ml for praziquantel. Proposed method was found to be simple, accurate, precise,
and quick could be used for regular analysis.
Keywords: UPLC, Abamectin, Praziquantel.