WJPR Citation
|
| All | Since 2020 | |
| Citation | 8502 | 4519 |
| h-index | 30 | 23 |
| i10-index | 227 | 96 |
CLEANING VALIDATION OF TABLET COMPRESSION MACHINE BY SWAB SAMPLING
Poonam D. Khalate*, Pratiksha S. Londhe, Bharatee P. Chaudhari, Vivekkumar K. Redasani
. Abstract Validation of cleaning technique using swab sampling and application in determining residual L-ascorbic acid in production area equipment, as well as confirmation of cleaning procedure efficiency. After producing L-ascorbic acid 10 mg chewable tablets, the swab sampling and UV method for residual determination of in L-ascorbic acid swab samples from equipment surfaces were established and verified. For LAscorbic Acid in tablet form, a unique, safe, and sensitive method of spectrophotometric measurement in the UV region has been devised. Water as diluents were used to develop and validate the technique for L- Ascorbic Acid. Keywords: Cleaning Validation, Linearity, Swab, Absorbance, UV Spectroscopy, L- Ascorbic Acid. [Full Text Article] [Download Certificate] |