DEVELOPMENT AND VALIDATION OF STABILITY INDICATING HPLC METHOD FOR SIMULATANEOUS ESTIMATION OF IMIPRAMINE AND DIAZEPAM IN COMBINED DOSAGE FROM
Pinky Verma, Jyoti Verma and Sanjay Kumar Kushwaha*
Abstract A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of Imipramine hydrochloride and Diazepam in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Phenomenex Prodigy C-18 column (150*4.6 mm, i.d., 5 ?m particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of methanol and 0.1%v/v ortho phosphoric acid (pH 3) in the ratio of 70:30 v/v. Results: A linear response was observed over the concentration range 5.00- 50.00 ?g/mL of diazepam and the concentration range 5.00-50.00 ?g/mL of Imipramine HCl. Limit of detection and limit of quantitation for Imipramine were 2.73 ?g/mL and 1.27 ?g/mL, and for Diazepam were 1.80 ?g/mL and 1.98 ?g/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of Imipramine HCl and Diazepam can be potentially used for the estimation of these drugs in combined dosage form. Keywords: . [Full Text Article] [Download Certificate] |