VALIDATION OF FLUIDIZED BED DRYER
V.P. Pandey, Srikanth.Paturi, A.G. Joshi and H.L.N. Rao
Abstract
The present study is undertaken to validate pharmaceutical equipment,
fluidized bed dryer (FBD), for ensuring quality products as well as
processes. After study of design qualification (DQ), installation
qualification (IQ), Operational qualification (OQ) and performance
qualification (PQ), it is found that machine is working satisfactorily
and its design and drawing reveal that the machine is according to the
order of the company. The drug chosen for this study is cephalexin and
it is observed that steam heating is more efficient than heat banks. It is
found that as the drying time increases, the percentage of fines in the
granules get increased. So shorter drying time will produce desired
granules with fewer fines.
Keywords: fluidized bed dryer, cephalexin.
[Full Text Article]